Subject: RE: CICS/TS statistics
From: Wakser, David (David.Wakser@infocrossing.com)
Date: Tue Jun 24 2008 - 11:30:13 EDT
Thanks, Dave. I'll work on this.
David Wakser
-----Original Message-----
From: owner-vse-l@Lehigh.EDU [mailto:owner-vse-l@Lehigh.EDU] On Behalf
Of industrynews@winwholesale.com
Sent: Tuesday, June 24, 2008 11:26 AM
To: VSE Discussion List
Subject: RE: CICS/TS statistics
owner-vse-l@Lehigh.EDU wrote on 06/24/2008 10:32:09 AM:
> The INQ STAT did, indeed, show an interval of 3 hours, which I have
> changed. But I cannot find a SIT parameter of STATINT. Did its name
> get changed?
You need a startup PLT program to do something like this:
EXEC CICS INQUIRE SYSTEM
RELEASE (INQ-RELEASE)
NOHANDLE
END-EXEC.
IF INQ-RELEASE > 0230
EXEC CICS SET STATISTICS
RECORDING(DFHVALUE(ON))
INTERVAL (+240000)
ENDOFDAY (+051730)
NOHANDLE
END-EXEC
END-IF.
Sincerely,
Dave Clark
WinWholesale Group Services
3110 Kettering Boulevard
Dayton, Ohio 45439 USA
(937) 294-5331
This archive was generated by hypermail 2b25 : Mon Jun 30 2008 - 23:50:13 EDT